Abstract
Bupivacaine hydrochloride 625 and 1250 micrograms/mL and hydromorphone hydrochloride 20 and 100 micrograms/mL in 0.9% sodium chloride injection were stable and compatible for up to 72 hours under fluorescent light when stored in polyvinyl chloride containers at 24 degrees C.
MeSH terms
-
Analgesics, Opioid / administration & dosage
-
Analgesics, Opioid / chemistry*
-
Anesthesia, Epidural
-
Anesthetics, Local / administration & dosage
-
Anesthetics, Local / chemistry*
-
Bupivacaine / administration & dosage
-
Bupivacaine / chemistry*
-
Drug Combinations
-
Drug Stability
-
Hydromorphone / administration & dosage
-
Hydromorphone / chemistry*
-
Pain Measurement
Substances
-
Analgesics, Opioid
-
Anesthetics, Local
-
Drug Combinations
-
Hydromorphone
-
Bupivacaine