Iodine-123 metaiodobenzylguanidine imaging and carbon-11 hydroxyephedrine positron emission tomography compared in patients with left ventricular dysfunction

Circ Cardiovasc Imaging. 2010 Sep;3(5):595-603. doi: 10.1161/CIRCIMAGING.109.920538. Epub 2010 Jun 9.

Abstract

Background: Although both (123)I-metaiodobenzylguanidine ((123)I-MIBG) imaging and (11)C-hydroxyephedrine ((11)C-HED) positron emission tomography (PET) are used for assessing cardiac sympathetic innervation, their relationship remains unknown. The aims were to determine whether (123)I-MIBG parameters such as heart-to-mediastinum ratio (H/M) are associated with quantitative measures by (11)C-HED PET and to compare image quality, defect size, and location between (123)I-MIBG single-photon emission computed tomography (SPECT) and (11)C-HED PET.

Methods and results: Twenty-one patients (mean left ventricular ejection fraction, 39 ± 15%) underwent (123)I-MIBG imaging and (11)C-HED PET. Early (15-minute), late (3-hour) H/M, and washout rate (WR) were calculated for (123)I-MIBG. Myocardial retention and WR was calculated for (11)C-HED. Using a polar map approach, defect was defined as the area with relative activity <60% of the maximum. Both the early (r=0.76) and late (r=0.84) (123)I-MIBG H/M were correlated with (11)C-HED retention. (123)I-MIBG WR was correlated with (11)C-HED WR (r=0.57). Defect size could not be measured in 3 patients because of poor quality (123)I-MIBG SPECT, whereas (11)C-HED defect was measurable in all patients. Although defect size measured by early or late (123)I-MIBG SPECT was closely correlated with that by (11)C-HED PET (early: r=0.94; late: r=0.88), the late (123)I-MIBG overestimated defect size particularly in the inferior and septal regions.

Conclusions: (123)I-MIBG H/M gives a reliable estimate of cardiac sympathetic innervation as measured by (11)C-HED PET. Furthermore, despite the close correlation in defect size, (11)C-HED PET appears to be more suitable for assessing regional abnormalities than does (123)I-MIBG SPECT.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • 3-Iodobenzylguanidine*
  • Aged
  • Aged, 80 and over
  • Ephedrine / analogs & derivatives*
  • Female
  • Heart / innervation*
  • Humans
  • Male
  • Middle Aged
  • Observer Variation
  • Positron-Emission Tomography*
  • Predictive Value of Tests
  • Radiopharmaceuticals*
  • Reproducibility of Results
  • Retrospective Studies
  • Stroke Volume
  • Sympathetic Nervous System / diagnostic imaging*
  • Sympathetic Nervous System / physiopathology
  • Tomography, Emission-Computed, Single-Photon*
  • Ventricular Dysfunction, Left / diagnostic imaging*
  • Ventricular Dysfunction, Left / physiopathology
  • Ventricular Function, Left

Substances

  • Radiopharmaceuticals
  • 3-hydroxyephedrine
  • 3-Iodobenzylguanidine
  • Ephedrine